Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes
Ready-to-use solutions provide savings in raw materials, labor and waste disposal.
Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes
Item #: 144239335

Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes

Item #: 144239335

MYR 1143

Price Details

Excluding Shipping & Custom charges ( Shipping and custom charges will be calculated on checkout )

*All items will import from AS

0 ratings Tuliskan ulasan
Dalam stok
AS Diimport dari kedai USA

QTY:

Pesan sekarang dan dapatkannya lebih kurang pada Monday, Julai 13
Our Top Logistics Partners
  • fedex
  • dhl
Ready-to-use solutions provide savings in raw materials, labor and waste disposal.
Waranti U-Care:
Tiada
Pilih pelan
fast shipping

Fast
Shipping

free return

Free
Return*

secure packaging

Secure Packaging

100% original products

100% Original Products

pci-dss

PCI DSS Compliance

iso certified

ISO 27001 Certified


paypal payment
visa payment
mastercard payment
american express payment
bank transfer payment
touchngo payment
Note: Step Down Voltage Transformer required for using electronics products of AS store (110-120). Recommended power converters Beli Sekarang.

What Stands Out

Enhanced Accuracy
TISAB II incorporates CDTA, improving the precision of fluoride measurements with ion-selective electrodes, effectively addressing common interference issues faced in conventional testing methods.
Mesra pengguna
Designed for simplicity, TISAB II allows laboratories and researchers to easily prepare and use the buffer, streamlining the process for consistent and reliable fluoride analysis.
Aplikasi Serbaguna
Ideal for a wide range of analytical environments, TISAB II supports various fluoride testing needs, making it the preferred choice for environmental, clinical, and industrial applications.

Maklumat produk

Shop Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes online at a best price in Malaysia. B0043EVKGC
Berat item1.5 lbs (680 gram)

Who Should Buy?

Suitable For
  • Teknikal Makmal

    Essential for technicians conducting fluoride analysis using ion selective electrodes in various laboratory environments.

  • Environmental Scientists

    Ideal for scientists assessing water quality and fluoride concentrations in environmental samples and field studies.

  • Penyelidik Akademik

    Beneficial for researchers in academia performing experiments related to fluoride chemistry and ion analysis.

Not Suitable For
  • Pengguna Rumah

    Not suitable for casual users without specialized knowledge or equipment for fluoride testing at home.

  • Non-technical Professionals

    May be overwhelming for professionals lacking technical expertise in ion selective electrode usage and chemical analysis.

  • Small Scale Applications

    Not recommended for small, infrequent tasks where comprehensive fluoride analysis techniques are unnecessary.

PENERANGAN PRODUK

Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes

Ada sebarang Pertanyaan? Berbual dengan kami

Soalan & Jawapan Pelanggan

  • soalan: What is TISAB II and its role in fluoride analysis?

    jawab: Total Ionic Strength Adjustment Buffer (TISAB II) is a specialized buffer solution used to stabilize ionic strength during fluoride analysis with ion-selective electrodes. It ensures accurate readings by maintaining consistent ionic conditions, which is crucial for the reliability of fluoride measurements in various samples, such as drinking water or biological fluids. The presence of CDTA in TISAB II enhances its effectiveness by binding with interfering metal ions, providing clearer and more precise analysis outcomes.
  • soalan: How do I use TISAB II with ion-selective electrodes?

    jawab: To utilize TISAB II effectively, first prepare your sample by diluting it as necessary, then add TISAB II in a defined ratio. This mixture can be directly introduced to an ion-selective electrode designed for fluoride detection. The buffer's function is to control ionic strength and minimize interferences, which is vital for obtaining precise and reproducible fluoride concentration readings in environmental samples or clinical assessments.
  • soalan: What are the main components of TISAB II?

    jawab: TISAB II primarily consists of a blend of buffers that stabilize pH and ionic strength, along with CDTA, which is a chelating agent that binds metallic ions. This combination enhances the accuracy of fluoride detection by minimizing the effect of contaminants and competing ions in the sample. By ensuring that the analytical conditions are consistent, TISAB II plays a key role in various applications, from water quality testing to food safety analysis.
  • soalan: Why is CDTA included in TISAB II?

    jawab: CDTA, or trans-1,2-diaminocyclohexane-N,N,N',N'-tetraacetic acid, is included in TISAB II to enhance the buffer’s ability to remove potential interference from metal ions. These ions can adversely affect the performance of the ion-selective electrode used for fluoride analysis. By binding with these interfering species, CDTA helps in obtaining more reliable and accurate fluoride concentration measurements, which is particularly important in regulatory compliance and research scenarios.
  • soalan: Can TISAB II be used for other ions aside from fluoride?

    jawab: While TISAB II is primarily designed for fluoride analysis, its buffered system can be adapted for other ions that require significant ionic strength adjustments. However, its specificity and the effectiveness of CDTA may not be the same for every ion type. Researchers often use TISAB II in conjunction with the appropriate ion-selective electrodes tailored for the specific analyte being tested, ensuring reliable readings in various analytical contexts.
  • soalan: What is the recommended storage condition for TISAB II?

    jawab: TISAB II should be stored in a cool, dark place, ideally at room temperature, to maintain its integrity. It is important to keep the buffer away from direct sunlight and extreme temperatures, which can degrade the solution over time. Proper storage ensures that the buffer maintains its optimal pH and ionic strength, crucial for accurate fluoride analysis when utilized in testing laboratories or field applications.
  • soalan: How does TISAB II affect the pH of a sample?

    jawab: TISAB II is formulated to maintain a neutral pH, typically around 5.0 to 5.5, which is ideal for fluoride measurements. Adding TISAB II to a sample helps to regulate its pH, crucial for ensuring that fluoride exists in a stable, measurable state. This controlled pH environment is essential in achieving accurate calibrations and results, especially in water quality assessments or food analysis, where pH can fluctuate significantly.
  • soalan: Is TISAB II compatible with all ion-selective electrodes?

    jawab: TISAB II is primarily used with ion-selective electrodes designed specifically for fluoride detection. However, compatibility can vary based on the electrode’s chemistry and design. It is advisable to consult the manufacturer’s guidelines for specific electrodes to ensure they are suitable for use with TISAB II. This compatibility check is particularly essential to avoid erroneous readings in scenarios like environmental monitoring or product testing.
  • soalan: What types of samples can be analyzed using TISAB II?

    jawab: TISAB II can be used to analyze a broad range of samples, including drinking water, wastewater, food products, and biological samples such as saliva or serum. Each sample type may require specific preparation steps, such as dilution prior to adding TISAB II, to ensure that fluoride concentration can be accurately quantified. This versatility makes TISAB II invaluable in laboratories working on environmental, health, or safety assessments.
  • soalan: Where can I buy Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes in Malaysia?

    jawab: You can purchase Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes at Ubuy. Ubuy offers a wide selection of chemical products and laboratory supplies, making it a reliable source for your analytical needs in Malaysia. The platform provides easy access to institution-quality reagents perfect for both professional and academic use.

RiccaChemical Electrodes Editorial Review

Tiada ulasan editorial ditemui

Customer Reviews & Ratings

5.0
1 rating pelanggan
  • 5 bintang
    100%
  • 4 bintang
    0%
  • 3 bintang
    0%
  • 2 bintang
    0%
  • 1 bintang
    0%

Ulas Produk Ini

Kongsikan pandangan anda dengan pelanggan lain

Product Price History

Maklumat penting

  • Pengehadan: Untuk produk penghantaran antarabangsa, harap maklum bahawa sebarang jaminan pengeluar mungkin tidak sah; pilihan perkhidmatan pengeluar mungkin tidak tersedia; manual produk, arahan, dan amaran keselamatan mungkin tidak dalam bahasa negara destinasi; produk-produk (dan bahan-bahan berkaitannya) mungkin tidak direka selaras dengan standard negara destinasi, spesifikasi, dan syarat pelabelan; dan produk-produk itu mungkin tidak mematuhi kepada voltan negara destinasi dan lain-lain standard elektrik (memerlukan penggunaan adaptor atau penukar aliran jika perlu). Penerima adalah bertanggungjawab untuk memastikan bahawa produk itu boleh diimport selaras dengan undang-undang negara destinasi. Apabila memesan dari Ubuy atau pihak afiliasinya, si penerima adalah merupakan pengimport dalam rekod dan mesti mematuhi kepada semua undang-undang dan peraturan negara destinasi.
  • Bukan semua produk yang tersenarai di Ubuy adalah untuk dijual, kerana Ubuy adalah enjin carian global. Produk-produk adalah tertakluk kepada peraturan eksport/perdagangan.